Technical data
6.8 Mechanical and climatic ambient conditions
Use prohibition
Without additional measures, SIMOTION D410 may not be used in
● Locations with a high percentage of ionizing radiation
● Locations with extreme operating conditions, e.g.,
● In systems, which require special monitoring, e.g.,
An additional measure for using SIMOTION D410 can, for example, be installation in
cabinets.
Mechanical ambient conditions
SIMOTION D410 meets the following standards for mechanical stress:
● Vibration load: DIN EN 60721-3-3, Class 3M4
● Shock load: DIN EN 60721-3-3, Class 3M4
● Free fall: DIN EN 60721-3-2, Class 2M1 and 2M2
● Toppling: DIN EN 60721-3-2, Class 2M1
The mechanical ambient conditions for SIMOTION D410 are listed in the following table in
the form of sinusoidal vibrations.
Table 6- 17
Mechanical ambient conditions
Ambient conditions
Vibration tested in
accordance with DIN EN
60068-2-6
Shock resistance tested in
accordance with DIN EN
60068-2-27
Vibration reduction
If SIMOTION D410 is subjected to larger shocks or vibrations, you must use suitable
measures to reduce the acceleration or the amplitude.
We recommend installation on shock-absorbing material (e.g. rubber-metal vibration
dampers).
86
– Dust accumulation
– corrosive vapors or gases
– Elevator installations
– Electrical systems in particularly hazardous rooms
Operation
10 to 57 Hz: 0.35 mm
58 to 200 Hz: 50 m/s²
10 g peak value, 6 ms duration
100 shocks in each axis vertical with respect
to each other
Transport (in packaging)
5 to 9 Hz: 3.5 mm
9 to 200 Hz: 10 m/s²
10 g peak value, 6 ms duration
100 shocks in each axis vertical with respect
to each other
SIMOTION D410
Manual, 02/2012

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 dpSimotion d410