Encoder Interface (Htl/Ttl/Ssi) - Siemens SIMOTION D410 PN Manual

Hide thumbs Also See for SIMOTION D410 PN:
Table of Contents

Advertisement

Connectable devices
The following devices can be connected to the PROFINET interface:
● PG/PC programming devices (communication with SIMOTION SCOUT / STEP 7 and
● SIMATIC HMI devices
● Distributed I/O
● Other SINAMICS drive units (e.g., CU310 PN or CU320 with CBE20)
See also
Connecting the PROFINET interface (D410 PN only) (Page 75)
3.6

Encoder interface (HTL/TTL/SSI)

The HTL/TTL/SSI encoder interface is used to connect external encoders.
Interface features
Table 3- 12
Features
Encoder interface
Connector type
Encoder power supply
Limit frequency
SSI baud rate
Resolution absolute position SSI
Max. cable lengths
1)
2)
SIMOTION D410
Manual, 02/2012
HMI)
Interface X23
For TTL incremental encoder
For HTL incremental encoder
For SSI absolute encoder
As of a cable length of 200 m, use a power supply cable with a cable cross-section ≥ 0.75 mm²!
Signal cables twisted in pairs and shielded.
3.6 Encoder interface (HTL/TTL/SSI)
Type
TTL or HTL incremental encoders (with
adjustable parameters)
Absolute encoder SSI
15-pin SUB-D connector
24 VDC/0.35 A or 5 VDC/0.35 A
500 kHz
100 . . .250 kBaud
30 bit
100 m (bipolar signals only)
100 m (for unipolar signals)
300 m (for bipolar signals)
100 m
Interfaces
2)
1) 2)
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion d410 dpSimotion d410

Table of Contents