Advertisement

Climatic ambient conditions
SIMOTION D410 may not be used under the following climatic ambient conditions:
Note
Observe the application ranges of the PM340 power modules along with their derating. For
further information, see SINAMICS documentation.
Table 6- 18
Climatic ambient conditions
Ambient conditions
Permissible ambient
temperature for operation
Maximum installation
altitude
Relative humidity
Air pressure
Pollution degree
Pollutant concentrations
SIMOTION D410
Manual, 02/2012
Application range
0 to +55 °C
2000 m to max. 5000 m above sea level
5 to 95 %
795 to 1080 hPa
2 acc. to EN 60664-1
Substances:
SO
: <0.5 ppm;
2
Relative humidity <60 %, no condensation
H
S: <0.1 ppm;
2
Relative humidity <60 %, no condensation
6.8 Mechanical and climatic ambient conditions
Remarks
Oil mist, ice formation, moisture condensation,
dripping water, spraying water, splashing water
and water jets are not permitted (EN 60204,
Part 1)
From an altitude of 2000 m, the maximum
ambient temperature decreases by 7°C every
1000 m.
Without condensation, corresponds to a relative
humidity (RH) severity level 2 according to
IEC 1131-2
-
-
Test:
10 ppm 4 days
1 ppm; 4 days
Technical data