Jog Operation Using A Panel Operator - YASKAWA Sigma-V Series User Manual

Ac servo drives
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

6 Trial Operation (Checking Servomotor Operation)
6.3

JOG Operation Using a Panel Operator

This section describes the procedure for executing a JOG operation using a panel
operator.
The operating section of the panel operator is behind the plastic plate at the top of the
front of the multi-winding drive unit. Pull the plungers and remove the plastic cover
to operate the panel operator.
Plungers
Step
Display after operation
1
2
3
6-6
Alternate
display
MODE/SET
MODE/SET
Keys
Turn ON the power to the multi-winding
drive unit, SERVOPACKs, and convert-
ers.
The forward run prohibited (P-OT) or
reverse run prohibited (N-OT) message is
displayed.
When the JOG operation is executed, P-
OT and N-OT are automatically disabled.
Press the MODE/SET Key to select the
utility function.
DATA/
Press the UP or DOWN Key to select
Fn002.
DATA/
Operation