YASKAWA Sigma-V Series User Manual page 70

Ac servo drives
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

(2)
Using a Dynamic Brake Unit from Another Company
• Using NO Contacts for the Dynamic Brake Contactor
SERVOPACK
CN115
24 V
DB
DB24
DBON
0 V
DB
∗ The above figure is for using a dynamic brake contactor with NO contacts. The dynamic
brake answer signal (a signal from NO auxiliary contacts) is input to CN1-45. To indicate an
error if the input signal to CN1-45 turns OFF (open) while the dynamic brake is activated, the
Pn515 parameter in the multi-winding drive unit must be set to n.E. If the dynamic
brake answer signal is not used, Pn515 is set to n.8 (default setting).
Note: 1. If you assign more than one signal to the same input circuit, OR logic will be used
and any of the input signals will cause the circuit to operate. This may result in unex-
pected operation.
2. The maximum current for DB24 and DBON is 300 mA.
4.6 Selecting and Connecting a Dynamic Brake Unit
CN1
47
Dynamic brake contactor
(Auxiliary contacts)
45*
DU
DV
DW
For I/O
power supply
24 V
0 V
Dynamic brake resistor
Main circuit surge
absorption unit
Coil surge
absorption unit
4-27