 Operation
• Always use the servomotor, multi-winding drive unit, SERVOPACK, and
converter in one of the specified combinations.
Failure to observe this caution may result in fire or malfunction.
• Conduct trial operations on the servomotor alone, with the motor shaft dis-
connected from the machine to avoid accidents.
Failure to observe this caution may result in injury.
• During trial operation, confirm that the holding brake works correctly. Fur-
thermore, secure system safety against problems such as signal line dis-
connection.
Failure to observe this caution may result in injury or damage to the product.
• Before starting operation with a machine connected, change the settings to
match the parameters of the machine.
Starting operation without matching the proper settings may cause the machine to
run out of control or malfunction.
• Do not frequently turn power ON and OFF.
• Frequently turning power ON and OFF causes elements inside the multi-winding
drive unit, SERVOPACK, and converter to deteriorate. Do not use the system
with an application that requires frequently turning power ON and OFF.
• After the actual operation starts, the allowable interval for turning power ON and
OFF is one hour or longer.
• When using JOG operations (Fn002) origin search operations (Fn003), or
EasyFFT operations (Fn206), the dynamic brake function does not work for
reverse overtravel or forward overtravel. Take necessary precautions.
Failure to observe this caution may result in damage to the product.
• When using the servomotor for a vertical axis, install safety devices to pre-
vent workpieces from falling due to alarms or overtravels. Set the servomo-
tor so that it will stop in the zero clamp state when overtravel occurs.
Failure to observe this caution may cause workpieces to fall due to overtravel.
• Before you start operation, always set the moment of inertia ratio (Pn103)
correctly.
Setting to an incorrect moment of inertia ratio may cause vibration.
• Do not touch the SERVOPACK or converter heat sink, regenerative resis-
tor, or servomotor while power is ON or soon after the power is turned OFF.
Failure to observe this caution may result in burns due to high temperatures.
• Do not make any extreme adjustments or setting changes of parameters.
Failure to observe this caution may result in injury or damage to the product due to
unstable operation.
• When an alarm occurs, remove the cause, reset the alarm after confirming
safety, and then resume operation.
Failure to observe this caution may result in damage to the product, fire, or injury.
• Do not use the holding brake of the servomotor for braking.
Failure to observe this caution may result in malfunction.
• An alarm or warning may occur if communications are performed with the
host controller while the SigmaWin+ or Digital Operator is operating.
If an alarm or warning occurs, it may stop the current process and stop the system.
CAUTION