4 Wiring and Connection
4.3.2 JUSP-MD3D11A (M-II Model)
∗1.
∗2.
∗3.
∗4.
∗5.
4-10
You must provide the 24-VDC power supply. Use a 24-VDC power supply with double
insulation or reinforced insulation.
You must provide a 24-VDC brake power supply.
If using a 90-VDC brake power supply, however, use one of the following power sup-
plies.
• For 200-V input voltage: LPSE-2H01-E
• For 100-V input voltage: LPDE-1H01-E
For details on grounding, refer to the design and maintenance user's manual for the
product.
Before connecting an external regenerative resistor, refer to 4.5 Selecting and Connecting
a Regenerative Resistor Unit.
For details on the dynamic brake unit, refer to 4.6 Selecting and Connecting a Dynamic
Brake Unit.