Connecting The Connectors - YASKAWA Sigma-V Series User Manual

Ac servo drives
Hide thumbs Also See for Sigma-V Series:
Table of Contents

Advertisement

4 Wiring and Connection

4.4.2 Connecting the Connectors

Terminals
CN103,
Control power output
CN104
connectors
4.4.2

Connecting the Connectors

Connect CN901 and CN103 on the SERVOPACK and converter as shown in the fol-
lowing figure.
Cable Name
IO signal connection
cable
24-VDC control
power supply cable
4-14
Name
Converter
SERVOPACK
Cable Model
JZSP-CVI02-A4-E
JZSP-CVG00-A4-E
Specifications
CN103 and CN104 output 24 VDC to the SERVO-
PACK.
For a 400-V system, the 24-VDC (±15%) input is output
unaltered from CN103. CN104 provides the same out-
put, but it is normally not necessary to connect it.
CN103: Control power supply input connector
24-VDC control power supply cable
I/O signal connection cable
CN901: I/O signal connector between the
SERVOPACK and converter
Cable
Length
This cable connects the CN901
0.4 m
connectors on the SERVOPACK
and converter.
This cable connects the
0.4 m
CN103(CN104) connectors on the
SERVOPACK and converter.
(cont'd)
Description