DOK-CONTRL-S67S3BKDI8*-AP03-EN-P
Rexroth IndraControl S67 Sercos Coupler 8 Digital Inputs (M8)
10.5.3
Example of an Error Message by Blink Code
Description
Group number
(tens place)
Pause
Group number
(ones place)
Pause
Flashes
Pause
Error code
Error code
(hundreds place)
Pause
Error code
(tens place)
Pause
Error code
(ones place)
Pause
Flashes
Pause
Error argument
Error argument
(hundreds place)
Pause
Error argument
(tens place)
Pause
Error argument
(ones place)
Pause
Process restarts when start sequence flashes
Tab. 10-3:
Overview of blink codes
The following example illustrates an error message, as indicated by the blink
code. An S-BUS-error is displayed, when the update of the software has
failed on the 6th I/O module.
Initiation:
Bosch Rexroth AG
Frequency
Repeats 0.5 s on and 0.5
s off
2 s
Repeats 0.5 s on and 0.5
s off
2 s
40 ms
2 s
Repeats 0.5 s on and 0.5
s off
2 s
Repeats 0.5 s on and 0.5
s off
2 s
Repeats 0.5 s on and 0.5
s off
2 s
40 ms
2 s
Repeats 0.5 s on and 0.5
s off
2 s
Repeats 0.5 s on and 0.5
s off
2 s
Repeats 0.5 s on and 0.5
s off
4 s
109/139
Diagnostics
Additional explanations
Repeated according to
group number
–
Repeated according to
group number
–
Initiation of error code
Repeated according to
error code
–
Repeated according to
error code
–
Repeated according to
error code
–
Initiation of error argument
Repeated according to
error argument
–
Repeated according to
error argument
–
Repeated according to
error argument
–