5 START-UP PROCEDURES

5.3 Operating System Software Installation Procedure

Operation in
MT Developer2
(Note)
The operating system software must be installed to the Motion CPU module by using
the MT Developer2.
The installation procedure is shown below.
START
Set a rotary switch1 (SW1) of Motion
CPU module to "A".
(Rotary switch 2 (SW2) is optional.)
Turn ON the Multiple CPU system
power supply.
Start the install of MT Developer2.
Set the connection method between
the personal computer and Multiple
CPU system in the Transfer Setup.
Select the operating system software
installed, and install it in the Motion
CPU module.
Dialog "Installation is completed" is
displayed.
Turn OFF the Multiple CPU system
power supply.
Set a rotary switch1 (SW1) and
switch2 (SW2) of Motion CPU module
to "0".
(Note): Install the operating system software by screen of MT Developer2.
Refer to help of MT Developer2 for details.
Ver.!
: Refer to Section 1.3 for the software version that supports this function.
END
5 - 7
Set to installation mode.
Refer to Section 2.5.1(3) for rotary switch.
Switch setting of factory default
Q173DSCPU/Q172DSCPU
: SW1 "0", SW2 "0" position
Q173DCPU(-S1)/Q172DCPU(-S1): SW1 "A", SW2 "0" position
Steady "INS" display.
RUN/STOP is ignored.
Only when the operating system software
(SV22) is installed on the Q173DSCPU/
Q172DSCPU, select one of the following
operation methods.
Ver.!
Virtual mode switching method
Advanced synchronous control method
The operating system software can be
installed normally by dialog display.
Set to mode operated by RAM.