Replacing the DIMM in the Secure Router 4134
Use the instructions in this section if you must replace the DIMM. The
DIMM is not hot swappable.
Average time to replace a DIMM: 2 minutes.
Prerequisites
•
Ensure the Secure Router 4134 is powered down.
•
Ensure you have a replacement DIMM.
•
Ensure you have a Phillips #2 screwdriver.
Procedure steps
Step
1
2
3
Replacing the DIMM in the Secure Router 4134 81
If you are replacing a PVM, also see
(page
76).
If you are not installing a PVM at this time, replace the service
access panel.
CAUTION
Do not open the Secure Router 4134 service access panel while
the unit is powered.
Action
Remove the two screws at the rear of the Secure Router 4134
that hold the service access panel secure. The following figure
shows the two screws that you must remove.
Slowly slide the access panel toward you until it is clear of the
Secure Router 4134.
Locate the DIMM module.
Nortel Secure Router 2330/4134
Installation — Hardware Components
NN47263-301 03.01 7 September 2009
Copyright © 2007-2008 Nortel Networks. All Rights Reserved.
"Installing the internal PVM"
--End--