76 Installing Secure Router 2330/4134 hardware components
Installing the internal PVM
Use the procedure in this section to install an internal PVM. If you are
replacing a PVM, also see
Average time to install the internal PVM module: 1 minute.
Prerequisites
•
Ensure the Secure Router 4134 has the power switched off.
•
Ensure you have a PVM ready to install before opening the service
access panel.
•
Ensure you have a Phillips #2 screwdriver.
Procedure steps
Step
1
2
3
CAUTION
Do not open the Secure Router 4134 service access panel while
the unit is powered.
"Removing the internal PVM" (page
Action
Remove the two screws at the rear of the Secure Router 4134
that hold the service access panel secure. Remove these two
screws only. See the following figure.
Slowly slide the access panel toward you until it is clear of the
Secure Router 4134.
Locate the internal PVM connector slot. The following figure
shows the location for installing the PVM.
Nortel Secure Router 2330/4134
Installation — Hardware Components
NN47263-301 03.01 7 September 2009
Copyright © 2007-2008 Nortel Networks. All Rights Reserved.
79).