DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
4
Combining the individual components
4.1
Documentations
4.2
Brief description of individual components
4.2.1
HCS01 - brief description and design
Brief description
Design, block diagram
4.3
Configuring the drive system
4.3.1
Converter
See
chapter "Documentations" on page 25
The compact converters HCS01 are part of the Rexroth IndraDrive Cs prod‐
uct range and are used to operate Rexroth IndraDyn motors or third-party
motors.
HCS01 types:
●
02: Mains connection voltage 3 AC 110 ... 230 V
●
03: Mains connection voltage 3 AC 200 ... 500 V
1)
Mains input with rectifier
2)
Braking resistor circuit; charging current limitation
3)
DC bus capacitances
4)
Inverter stage with output to motor
5)
DC bus connection
Fig. 4-1:
HCS01 block diagram
The selection of the appropriate converter depends on
●
Mains type
●
Mains Voltage
●
Mains supply (1-phase or 3-phase)
Bosch Rexroth AG