236/341
Bosch Rexroth AG
Technical data of the components
Description
Power factor of fundamental com‐
ponent DPF at P
DC_cont
phase, without mains choke)
Power factor of fundamental com‐
ponent DPF at P
(single-
DC_cont
phase, with mains choke)
Power factor of fundamental com‐
ponent DPF at P
DC_cont
phase, with mains choke)
Description
Mains frequency
Mains frequency tolerance
Maximum allowed mains frequen‐
cy change
Rotary field condition
Short circuit current rating
Nominal mains voltage
Single-phase mains voltage
Three-phase mains voltage at TN-
S, TN-C, TT mains
Three-phase mains voltage at IT
mains
1)
Three-phase mains voltage at
Corner-grounded-Delta mains
Tolerance rated input voltage U
Symbol
Unit
(three-
cosφ
h1
cosφ
h1
(three-
cosφ
h1
1) 2)
3)
4)
5) 6) 7) 8) 10) 11) 12) 13) Find interim values by interpolation
9)
Tab. 7-42:
HCS - Mains voltage supply data
Mains voltage supply data
Symbol
Unit
f
Hz
LN
Hz
Δf
/Δt
Hz/s
LN
SCCR
A rms
U
V
LN_nenn
U
V
LN
U
V
LN
U
V
LN
U
V
LN
2)
%
LN
DOK-INDRV*-HCS01******-PR05-EN-P
Rexroth IndraDrive CsDrive Systems with HCS01
HCS01.1E
HCS01.1E
HCS01.1E
-W0003-
-W0006-
-W0009-
_-02
_-02
_-02
0.99
Mains voltage > U
grounded neutral point, do not use autotransform‐
ers!
Otherwise use HNL mains choke
Maximum allowed number of switch-on processes:
250000
Copper wire; PVC-insulation (conductor tempera‐
ture 90 °C; T
≤ 40 °C) in accordance with
a
NFPA 79 chapter 12 and UL 508A chapter 28
HCS01.1E
HCS01.1E
HCS01.1E
-W0005-
-W0008-
-W0018-
_-03
_-03
_-03
50...60
None
42000
3 AC 400
Not allowed
200...500
200...230
200...230
± 10
HCS01.1E
HCS01.1E
-W0013-
-W0018-
_-02
_-02
-
-
Last modification: 2012-06-28
: Use a transformer with
LN
HCS01.1E
HCS01.1E
-W0028-
-W0054-
_-03
_-03
± 2
2
Last modification: 2012-06-28