Ipr-Set Fixed Data Rate; Command Syntax; Description; Defined Values - Huawei MU509 At Command Interface Specification

Hsdpa lga module
Hide thumbs Also See for MU509:
Table of Contents

Advertisement

HUAWEI MU509 HSDPA LGA Module
AT Command Interface Specification
5.5 +IPR–Set Fixed Data Rate

5.5.1 Command Syntax

Command
+IPR[=<rate>]
+IPR?
+IPR=?

5.5.2 Description

This numeric extended-format parameter specifies the data rate at which the DCE will
accept command set. It may be used to select operation at rates at which the DCE is
not capable of automatically detecting the data rate being used by the DTE. The
default value is 115200 bps.
If <rate> is not included in the command, the baud rate will be set to 115200bps.
The settings will be stored in NV automatically, and will be restored from NV when
power on.
Notes:

5.5.3 Defined Values

<rate>: valid numeric values, bps
600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400
Issue 04 (2013-01-28)
The auto detectable rates are not support currently, the interface is reserved for extended
use, so the first parameters of the TEST command will return brackets without value.
If the UART baud rate is higher than the radio bearer rate, and the transmit data rate is high,
the data may be lost.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Serial Interface Control Commands
Possible response(s)
<CR><LF>OK<CR><LF>
In case of error:
<CR><LF>ERROR<CR><LF>
<CR><LF>+IPR: <rate><CR><LF>
<CR><LF>OK<CR><LF>
<CR><LF>+IPR: (list of supported auto detectable
<rate>s),(list of supported fixed-only
<rate>s))<CR><LF>
<CR><LF>OK<CR><LF>
62