The "AT+CMEE" will be set <n> to 0.
3.13 +CFUN–Set Operation Mode

3.13.1 Command Syntax

Command
+CFUN[=<fun>[,<rst>]]
+CFUN?
+CFUN=?

3.13.2 Description

The SET command is used to set the MS mode or restart the MS.
The READ command is used to return the current mode.
The TEST command is used to return the supported parameter values.

3.13.3 Defined Values

<fun>:
0: Set as LPM (low power consumption) mode (previous mode must not be offline)
1: Set as online mode (default value) (previous mode must not be offline)
<rst>: whether to restart MT before setting.
0: Do not reset the MT before setting it to <fun> power level (default value).
1: Reset the MT before setting it, and <fun> must be set to 1.
Note:
Issue 04 (2013-01-28)
AT+CFUN without value will set as LPM mode.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Possible response(s)
<CR><LF>OK<CR><LF>
In case of MS-related error:
<CR><LF>+CME ERROR: <err><CR><LF>
<CR><LF>+CFUN: <fun><CR><LF>
<CR><LF>OK<CR><LF>
In case of MS-related error:
<CR><LF>+CME ERROR: <err><CR><LF>
<CR><LF>+CFUN: (list of supported <fun>s), (list of
supported <rst>s)<CR><LF>
<CR><LF>OK<CR><LF>