YASKAWA Sigma-7-Series Product Manual page 169

With ft/ex specification for transfer and alignment application with special motor, sgm7d motor
Table of Contents

Advertisement

Parameter
Name
No.
Pn902 to
Parameter Bank Mem-
2
Pn910
ber Definition
Parameter Bank Data
Pn920 to
2
(Not saved in nonvolatile
Pn95F
memory.)
*1.
Refer to the following manual for details.
Σ
Σ
-7-Series
-7S SERVOPACK with MECHATROLINK-III Communications References Product Manual (Manual
No.: SIEP S800001 28)
Σ
Σ
-7-Series Drive
-7S SERVOPACK with MECHATROLINK-III Communications References and RJ-45 Connec-
tors Product Manual (Manual No.: SIEP S800001 62)
*2.
Refer to the following manual for details.
Σ-7-Series AC Servo Drive MECHATROLINK-III Communications Standard Servo Profile Command Manual
(Manual No.: SIEP S800001 31)
*3.
Set a percentage of the motor rated torque.
*4.
These parameters are for SERVOPACKs with a Safety Module. Refer to the following manual for details.
Σ-V-Series/Σ-V-Series for Large-Capacity Models/Σ-7-Series User's Manual Safety Module (Manual No.: SIEP
C720829 06)
*5.
Normally set this parameter to 0. If you use an External Regenerative Resistor, set the capacity (W) of the Exter-
nal Regenerative Resistor.
*6.
The upper limit is the maximum output capacity (W) of the SERVOPACK.
*7.
These parameters are for SERVOPACKs with the dynamic brake option. Refer to the following manual for
details.
Σ-7-Series AC Servo Drive Σ-7S/Σ-7W SERVOPACK with Dynamic Brake Hardware Option Specifications Prod-
uct Manual (Manual No.: SIEP S800001 73)
*8.
This parameter is valid only when the MECHATROLINK-III standard servo profile is used.
*9.
The parameter setting is enabled after SENS_ON command execution is completed.
*10.
Change the setting when the reference is stopped (i.e., while DEN is set to 1). If you change the setting during
operation, the reference output will be affected.
*11.
The settings are updated only if the reference is stopped (i.e., only if DEN is set to 1).
*12.
Refer to the following manual for details.
Σ-7-Series AC Servo Drive MECHATROLINK-II Communications Command Manual (Manual No.: SIEP S800001
30)
*13.
This parameter is valid only when the MECHATROLINK-II-compatible profile is used.
*14.
The setting of Pn842 is valid while Pn817 is set to 0.
*15.
The setting of Pn844 is valid while Pn818 is set to 0.
*16.
You can check overspeed detection speed with MECHATROLINK-III Common Parameter 05 PnA0A (Maximum
Output Speed).
Setting
Setting
Default
Range
Unit
Setting
0000h to
0h
08FFh
0000h to
0h
FFFFh
6.2 List of Servo Parameters
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
Rotary
Setup
restart
Immedi-
Rotary
Setup
ately
Refer-
ence
*2
*2
6
6-39