YASKAWA Sigma-7-Series Product Manual page 149

With ft/ex specification for transfer and alignment application with special motor, sgm7d motor
Table of Contents

Advertisement

Parameter
Name
No.
Input Signal Selections
2
2
N-OT (Reverse Drive Prohibit) Signal Allocation

n.
X

n.
X
Reserved parameter (Do not change.)
Pn50B
/P-CL (Forward External Torque Limit Input) Signal Allocation

n.
X
/N-CL (Reverse External Torque Limit Input) Signal Allocation

n.X
Setting
Setting
Range
Unit
0000h to
FFFFh
0
Enable reverse drive when CN1-13 input signal is ON (closed).
1
Enable reverse drive when CN1-7 input signal is ON (closed).
2
Enable reverse drive when CN1-8 input signal is ON (closed).
3
Enable reverse drive when CN1-9 input signal is ON (closed).
4
Enable reverse drive when CN1-10 input signal is ON (closed).
5
Enable reverse drive when CN1-11 input signal is ON (closed).
6
Enable reverse drive when CN1-12 input signal is ON (closed).
7
Set the signal to always prohibit reverse drive.
8
Set the signal to always enable reverse drive.
9
Enable reverse drive when CN1-13 input signal is OFF (open).
A
Enable reverse drive when CN1-7 input signal is OFF (open).
B
Enable reverse drive when CN1-8 input signal is OFF (open).
C
Enable reverse drive when CN1-9 input signal is OFF (open).
D
Enable reverse drive when CN1-10 input signal is OFF (open).
E
Enable reverse drive when CN1-11 input signal is OFF (open).
F
Enable reverse drive when CN1-12 input signal is OFF (open).
0
Active when CN1-13 input signal is ON (closed).
1
Active when CN1-7 input signal is ON (closed).
2
Active when CN1-8 input signal is ON (closed).
3
Active when CN1-9 input signal is ON (closed).
4
Active when CN1-10 input signal is ON (closed).
5
Active when CN1-11 input signal is ON (closed).
6
Active when CN1-12 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-13 input signal is OFF (open).
A
Active when CN1-7 input signal is OFF (open).
B
Active when CN1-8 input signal is OFF (open).
C
Active when CN1-9 input signal is OFF (open).
D
Active when CN1-10 input signal is OFF (open).
E
Active when CN1-11 input signal is OFF (open).
F
Active when CN1-12 input signal is OFF (open).
The allocations are the same as the /P-CL (Forward External Torque Limit
0 to F
Input) signal allocations.
6.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
8882h
Rotary
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
*1
6
6-19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents