6.2 List of Servo Parameters
Parameter
No.
Pn009
Pn00A
6-6
Name
Application Function
2
Selections 9

n.
X
Reserved parameter (Do not change.)
Current Control Mode Selection
0
Use current control mode 1.

n.
X
• SERVOPACK Models SGD7S-2R8A and -2R8F: Use current control mode 1.
1
• SERVOPACK Model: SGD7S-120A: Use current control mode 2.
2
Use current control mode 2.
Speed Detection Method Selection

n.
X
0
Use speed detection 1.
1
Use speed detection 2.

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections A
Motor Stopping Method for Group 2 Alarms
Apply the dynamic brake or coast the motor to a stop (use the stopping
0
method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
1
torque. Use the setting of Pn001 = n.X for the status after stopping.

n.
X
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
2
torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in Pn30A. Use
3
the setting of Pn001 = n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in Pn30A and
4
then let the motor coast.
Stopping Method for Forced Stops
Apply the dynamic brake or coast the motor to a stop (use the stopping
0
method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
1
torque. Use the setting of Pn001 = n.X for the status after stopping.

n.
X
Decelerate the motor to a stop using the torque set in Pn406 as the maximum
2
torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in Pn30A. Use
3
the setting of Pn001 = n.X for the status after stopping.
Decelerate the motor to a stop using the deceleration time set in Pn30A and
4
then let the motor coast.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
0010h
0121h
0000h to
0001h
0044h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
Rotary
Tuning
restart
After
Rotary
Setup
restart
Continued on next page.
Refer-
ence
*1
*1