Data Mover I/O module types
Four-port 6-Gb/s SAS I/O module LEDs
The four-port 6-Gb/s SAS I/O module has two types of status LEDs.
LEDs and
Table 26 on page 63
Link/activity LED
Figure 50 Four-port 6-Gb/s SAS I/O module LEDs
Table 26 Four-port 6-Gb/s SAS I/O module LEDs
LED
Color
State
Power/Fault
Green
On
Amber
On
Off
Link/activity Blue
On
Blinking
Off
Four I/O module types are supported by the File/Unified VNX8000 platform Data Mover.
IMPORTANT
When adding new I/O modules, always install I/O modules in sets to each Data Mover
within the File/Unified VNX8000 platform or failover group. All Data Movers in the
File/Unified VNX8000 platform or failover group must have the same type of I/O modules
in the same slots. For more information, refer to the
Mover
document available online at
then select Add VNX hardware. Next, follow the steps in the wizard.
describes them.
Power/fault LED
VNX-000581
Description
I/O module is powered up.
I/O module has faulted.
I/O module is powered down.
Network connection
Transmit/receive activity
No activity
Adding I/O modules to the Data
https://mydocs.emc.com/VNX/
EMC VNX8000 Hardware Information Guide
I/O modules
Figure 50
shows the
and go to VNX tasks,