CPU
The CPU modules in the DME contain the power, fault, and unsafe-to-remove LEDs.
Figure 11
shows the CPU LEDs.
AC
Figure 11 CPU LEDs
Table 7
describes the CPU LEDs.
Table 7 CPU LEDs
LED
Color
State
Power
Green
On
Off
Fault
Amber
On
Blinking
Blue
Blinking
(see
Note)
Off
Unsafe to
White
On
remove
Off
Note: The fault LED changes color from amber to blue when the operating system is loading, see
step 4 in the description.
CPU power LED
AC
Description
Data Mover is powered up and all components in the Data
Mover are operating properly.
Data Mover is powered down.
Data Mover has faulted.
Data Mover goes through six stages of power up:
1. Executes a BIOS check, blinking once every 4 seconds
2. Executes a POST check, blinking once every second
3. Loads the operating system, blinking four times a second
4. Operating system loaded, blinking once every 4 seconds
5. Operating system starting drivers, blinking once every
second
6. Operating system drivers operating, blinking four times a
second
Data Mover operating normally.
Data Mover is unsafe to remove.
Data Mover is safe to remove.