Eight- and sixteen-bus DAE cabling
Sixteen-bus factory-shipped VNX8000 system
154
EMC VNX8000 Hardware Information Guide
The back end port numbering for a VNX8000 is set at system test (at the factory). Ports are
identified and numbered, low to high, left to right. The 6-Gb/s SAS I/O modules are in
slots 4, 5, 6, and 10 of Storage Processors A and B.
IMPORTANT
Slot 5, port 0 is reserved for connection to the vault drives.
A sixteen bus VNX8000 system with 6-Gb/s SAS I/O modules in slot 4, 5, 6 and 10
supports up to sixteen loops using standard x4 SAS cables
Table 56 A (sixteen-bus) VNX8000 scenario
I/O module slot
number
Port
4
0
4
1
4
2
4
3
5
0
5
1
5
2
5
3
6
0
6
1
6
2
6
3
10
0
Back-end
SP A an B cable labels
loop #
(white w/black text)
1
SP A SAS 4 Port 0
SP B SAS 4 Port 0
2
SP A SAS 4 Port 1
SP B SAS 4 Port 1
3
SP A SAS 4 Port 2
SP B SAS 4 Port 2
4
SP A SAS 4 Port 3
SP B SAS 4 Port 3
0
SP A SAS 5 Port 0
SP B SAS 5 Port 0
5
SP A SAS 5 Port 1
SP B SAS 5 Port 1
6
SP A SAS 5 Port 2
SP B SAS 5 Port 2
7
SP A SAS 5 Port 3
SP B SAS 5 Port 3
8
SP A SAS 6 Port 0
SP B SAS 6 Port 0
9
SP A SAS 6 Port 1
SP B SAS 6 Port 1
10
SP A SAS 6 Port 2
SP B SAS 6 Port 2
11
SP A SAS 6 Port 3
SP B SAS 6 Port 3
12
SP A SAS 10 Port 0
SP B SAS 10 Port 0
(Table
56).
Back-end loop cable
label colors
Blue
Black
Green
Brown
Orange
Cyan
Purple
Pink
Yellow
Medium gray
Red
Tan
Light blue/green

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vnx8000

Table of Contents