Configuring with Web Based Management
5.7 "Layer 2" menu
5.7.3.5

MST Port

Configuration of the Multiple Spanning Tree port parameters
On this page, you set the parameters for the ports of the configured multiple spanning tree
instances.
Description
Table 1 has the following columns:
● Column 1
Shows that the settings are valid for all ports of table 2.
● MSTP Status
Select the setting for all ports from the drop-down list. If "No Change" is selected, the
entries of the corresponding column in Table 2 remain unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
The page contains the following box:
● "MSTP Instance ID" drop-down list
In the drop-down list, select the ID of the MSTP instance.