5.2 Login
Login with HTTP
There are two ways in which you can log in via HTTP. You either use the login option in the
center of the browser window or the login option in the upper left area of the browser
window.
The following steps apply when logging in whichever of the above options you choose:
1. Enter the following in the "Name" input box:
– "admin": With this user type, you can change the settings of the device (read and write
– "user": With this user type, you cannot change any of the settings of the device (read
2. Enter your password in the "Password" input box.
When you log in for the first time or following a "Restore Factory Defaults und Restart",
enter the standard password in the "Password" input box.
– "admin": standard password "admin"
– "user": standard password "user"
3. Click the "Login" button or confirm your entry with "Enter".
When you log in for the first time or following a "Restore Factory Defaults and Restart",
you will be prompted to change the password. The new password must be at least 6
characters long. You need to repeat the password as confirmation. The password entries
must match. Click the "Set Values" to complete the action and activate the new
password.
Once you have logged in successfully, the start page appears.
Login with HTTPS
Web Based Management also allows you to connect to the device over the secure
connection of the HTTPS protocol. Follow these steps:
1. Click on the link "Switch to secure HTTP" on the login page or enter "https://" and the IP
address of the device in the address box of the Internet browser.
2. Confirm the displayed certificate warning.
The login page of Web Based Management appears.
3. Enter the following in the "Name" input box:
– "admin": With this user type, you can change the settings of the device (read and write
– "user": With this user type, you cannot change any of the settings of the device (read
40
access to the configuration data).
access to the configuration data).
access to the configuration data).
access to the configuration data).
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03