Configuring with Web Based Management
5.9 "Security" menu
Description
The page contains the following boxes:
● Reauthentication Mode
Specify who sets the time after which the clients are forced to reauthenticate.
– Disabled
– Server
– Local
● Reauthentication Interval [s]
If time management is local, enter the period of validity of the authentication in seconds.
The minimum time is 1 minute (enter 60), the maximum time is 12 hours (enter 43200).
The default is one hour (3,600 seconds).
The table has the following columns:
● Server IP Address
Here, enter the IP address or the FQDN name of the RADIUS server.
● Server Port
Enter the input port on the RADIUS server.
● Shared Secret
Enter the password of the RADIUS server.
For the password, ASCII code 0x20 to 0x7e is used.
● Shared Secret Confirmation
Confirm the password.
● Max. Retransmissions
Enter the maximum number of connection attempts.
● Primary Server
Specify whether or not this server is the primary server.
– yes: Primary server
– no: Backup server.
● Status
With this check box, you can enable or disable the RADIUS server
226
Reauthentication mode is disabled.
Enables time management on the server.
Enables local time management. In "Reauthentication Interval", specify the time of
validity.
SCALANCE W760/W720 to IEEE 802.11n Web Based Management