5.5.12.6
SIMATIC Time Client
Time setting via SIMATIC time client
Description
The page contains the following boxes:
● SIMATIC Time Client
Select this check box to enable the device as a SIMATIC time client.
● Current System Time
This box displays the current system time.
● Last Synchronization Time
This box is read-only and shows when the last time-of-day synchronization took place.
● Last Synchronization Mechanism
This box displays how the last time-of-day synchronization was performed. The following
methods are possible:
– Not set
– Manual
– SNTP
– NTP
– SIMATIC
Procedure
1. Click the "SIMATIC Time Client" check box to enable the SIMATIC Time Client.
2. Click the "Set Values" button.
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
The system time was not set.
Manual time setting
Automatic time-of-day synchronization with SNTP
Automatic time-of-day synchronization with NTP
Automatic time-of-day synchronization using the SIMATIC time frame
Configuring with Web Based Management
5.5 "System" menu
159