Parameter assignment/addressing
6.9 DR07 Interface parameters
6.9.12
Modbus TCP Unit Identifier, port, SWAP options
The following options are available for the Modbus TCP/IP interface:
Selection code
[modbusUnitIdentifier1]
-1 (default)
Modbus TCP port connection [modbusPort]
Defines the port for the Modbus connections.
6.9.13
Byte/Word swap options [byteSwap16Bit] [byteSwap32Bit] [wordSwap32Bit]
Defines the format used for transfer over the Ethernet interface (MODBUS TCP IP).
6.9.14
RS485 protocol
Configures the serial interface RS485.
Selection code
0 (default)
6.9.15
I/O process values 1 to 4 [ioProcessValue1 to ioProcessValue4]
You can transfer up to four selectable I/O process values from the electronic weighing system
to the CPU cyclically via the I/O. The following I/O process values can be selected:
Table 6-2
I/O process value
No element is selected
Gross process weight 1
Net process weight 1
Tare process weight
Net weight
Gross / net weight x10 (legal-for-trade)
Gross weight
Tare weight (legal-for-trade)
Gross process weight 2
Net process weight 2
Unfiltered digit value
Digits filtered by F1
Digits filtered by F2
76
Function
Unit Identifier is not evaluated
Selection table for I/O process values 1, 2, 3 and 4
Protocol
Deactivated
Selection code
0
1
2
3
4
5
6
7
8
9
10
11
12
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA