● Alternative DFS Channel
If you have enabled the "DFS" function on the Basic Wizard page "Radio Settings",
specify the alternative channel here. If you want the access point to search for a free
channel itself, use "Auto". If you want to use a fixed channel, select the required channel
from the drop-down list.
● HT Channel Width [MHz]
You can specify the channel bandwidth with the IEEE 802.11n transmission standard.
The following settings are possible.
– 20
– 40 up
– 40 down
Table 2 contains the following columns:
● Port
Shows the VAP interface.
● SSID
Enter the SSID. The length of the character string for SSID it is 1 to 32 characters.
The ASCII code 0x20 to 0x7e is used for the SSID.
After completing the Basic Wizard, you can define further SSIDs with "Interfaces > WLAN
> AP".
5.3.1.8

Client Settings

Introduction
On this Basic Wizard page, you specify the configuration for clients, for example the
assignment of the MAC address.
Note
This page is only available in client mode.
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
Channel bandwidth 20 MHz
Channel bandwidth 40 MHz. The configured channel and the neighboring channel
above it are used.
Channel bandwidth 40 MHz. The configured channel and the neighboring channel
below it are used.