Configuring with Web Based Management
5.5 "System" menu
● Daylight Saving Time
Shows whether the daylight saving time changeover is active:
– active (+1 hour)
– inactive (+0 hours)
● Time Zone
In this box, enter the time zone you are using in the format "+/- HH:MM". The time zone
relates to UTC standard world time. Settings for daylight-saving and standard time are
taken into account in this box by specifying the time offset.
● NTP Server IP Address
Enter the IP address or the FQDN name of the NTP server.
● NTP Server Port
Enter the port of the NTP server.
The following ports are possible:
– 123 (standard port)
– 1025 to 36564
● Poll Interval(s)
Here, enter the interval between two-time queries. In this box, you enter the query interval
in seconds. Possible values are 64 to 1024 seconds.
Procedure
1. Click the "NTP Client" check box to enable the automatic time setting using NTP.
2. Enter the necessary values in the following boxes:
– Time zone
– IP address or FQDN name of the NTP server
– NTP server port
– Query interval
3. Click the "Set Values" button.
158
The time in "Current System Time" is daylight saving time.
The time in "Current System Time" is not daylight saving time.
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03