● "Local Port" input box
Enter the number of the port. This is the new destination port to which the incoming frame
will be forwarded. If the setting is intended to apply to a port range, enter the range with
start port "-" end port, for example 30 - 40.
translation.
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Enable
Select the check box in the required row. The entry is used for the address assignment
● Interface
Shows the interface to which the settings relate.
● Traffic Type
Shows whether UDP or TCP frames are assigned to the global port.
● Dynamic Global IP
Shows whether or not dynamic address conversion is used.
● Global IP Address
Shows the global IP address to which the local IP address will be translated.
● Global Port
Shows the global port.
● Local IP Address
Shows the IP address of the node in the local network.
● Local Port
Shows the number of the local port.
Procedure
1. From the "Traffic Type" drop-down list, select the protocol for which the address
assignment is valid.
2. Enter the number of the global port or a port range in "Global Port".
3. Enter the IP address of the node in the local network in "Local IP Address".
4. Enter the number of the local port or a port range in "Local Port".
5. Click the "Create" button. A new entry is generated in the table.
6. Click the "Set Values" button. The device is restarted.
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03
If the local port and global port are the same, the frames will be forwarded without port
Configuring with Web Based Management
5.8 "Layer 3" menu