Mst General - Siemens SIMATIC NET SCALANCE W760 Series Configuration Manual

Industrial wireless lan to ieee 802.11n web based management
Table of Contents

Advertisement

Configuring with Web Based Management
5.7 "Layer 2" menu
● P.t.P.
– Enabled
– Disabled
● Hello Time
Enter the interval after which the bridge sends configuration BPDUs. As default, 2
seconds is set.
Range of values: 1-2 seconds
Note
The port-specific setting of the Hello time is only possible in MSTP compatible mode.
Procedure
1. In the input cells of the table row, enter the values of the port you are configuring.
2. From the drop-down lists of the cells of the table row, select the values of the port you are
configuring.
3. Click the "Set Values" button.
5.7.3.4

MST general

Multiple Spanning Tree configuration
With MSTP, in addition to RSTP, several VLANs can be managed in a LAN with separate
RSTP trees.
210
Shows that a point-to-point link exists.
Shows that no point-to-point link exists
SCALANCE W760/W720 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C350-03