Input Plate Option - Danfoss VLT Automation Drive FC 300 Operating Instructions Manual

Hide thumbs Also See for VLT Automation Drive FC 300:
Table of Contents

Advertisement

3. How to Install
NB!
Please see the

3.4.4. Input plate option

This section is for the field installation of input option kits available for VLT frequency converters in all D and E frames.
3
Do not attempt to remove RFI filters from input plates. Damage may occur to RFI filters if they are removed from the input plate.
NB!
Where RFI filters are available, there are two different type of RFI filters depending on the input plate combination and the RFI filters
interchangeable. Field installable kits in certain cases are the same for all voltages.
380 - 480 V
380 - 500 V
D1
All D1 power sizes
D2
All D2 power sizes
E1
FC 102/ 202: 315 kW
FC 302: 250 kW
FC 102/ 202: 355 - 450
kW
FC 302: 315 - 400 kW
525 - 600 V
525 - 690 V
D1
FC102: 75 kW
FC202: 45-90 kW
FC302: 37-75 kW
FC102/ 302: 90-132 kW
FC202: 110-160 kW
D2
All D2 power sizes
E1
FC102/ 302: 355-400 kW
FC202: 450-500 kW
FC102: 450-500 kW
FC202: 560-630 kW
FC302: 500-560 kW
Kit contents
-
Input plate assembled
-
Instruction sheet 175R5795
Cautions
-
-
-
-
42
Pedestal Kit Instruction Manual, 175R5642
Fuses
176F8442
176F8443
176F0253
176F0254
Fuses
175L8829
175L8442
175L8827
176F0253
176F0254
Frequency converter contains dangerous voltages when connected to line voltage. No disassembly should be attempted with
power applied
Electrical parts of the frequency converter may contain dangerous voltages even after the mains have been disconnected.
Wait a minimum of 15 minutes after disconnecting the mains before touching any internal components to ensure that capac-
itors have fully discharged
The input plates contain metal parts with sharp edges. Use hand protection when removing and reinstalling.
E1 frame input plates are heavy (20-35 kg depending on configuration). It is recommended that the disconnect switch be
removed from input plate for easier installation and be reinstalled on the input plate after the input plate has been installed
on the drive
MG.33.U2.02 - VLT
, for further information.
Disconnect Fuses
RFI
176F8450
176F8444
176F8441
176F8445
176F0255
176F0257
176F0256
176F0257
Disconnect Fuses
RFI
175L8828
175L8777
175L8445
175L8777
175L8826
175L8825
176F0255
NA
176F0258
NA
-
Modification Label
-
Disconnect handle template (units w/ mains disconnect)
®
is a registered Danfoss trademark
®
VLT
Automation Drive FC 300
Operating Instructions High Power
RFI Fuses
RFI
Disconnect
Fuses
176F8448
176F8446
176F8449
176F8447
176F0258
176F0260
176F0259
176F0262
RFI Fuses
RFI
Disconnect
Fuses
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA

Advertisement

Table of Contents
loading

Table of Contents