5. Conversion and maintenance

5.2.2 Replacing valves or cover plates

Dismantling
Mounting
Festo P.BE−MPAL−EN en 1008NH
Proceed as follows:
Use a screwdriver with a narrow blade to loosen the
·
fastening screws and remove the components from the
sub−bases (see Fig. 5/1).
Fig. 5/1: Dismantling valves or cover plates
Proceed as follows:
1. Check the seals for damage, especially the cord seals.
2. Replace seals if they are damaged.
3. Make sure that the cord seal between the sub−base and
components is in the correct position: The cord seal must
sit in the component cut−outs.
5−5