2. Mounting
Dismantling
2.3.2 Additional mountings of the valve terminal
Valve terminal MPA−L
CPX terminal
Festo P.BE−MPAL−EN en 1008NH
Proceed as follows:
1. Prevent a hanging−mounted valve terminal MPA−L from
falling down before you loosen it from the mounting
surface.
2. Loosen the mounting screws (see Tab. 2/2).
3. Remove the valve terminal MPA−L from the mounting
surface.
The valve terminal MPA−L has standard mounting points for
wall mounting.
The use of additional mountings, type VMPAL−BD, is necessary
under the following conditions (Tab. 2/3):
For increased vibration/shock loads (limits for vibrations
and shock see Appendix A, Tab. A/2
and:
For valve terminal MPA−Ls that are longer than 200 mm,
additional mountings must be used every 130 mm.
A CPX terminal on the valve terminal MPA−L with four or more
interlinking blocks must be fitted with additional mounting
clips, type CPXBG−RW−..., (see CPX system description).