GE UR Series Instruction Manual page 385

Line differential relay
Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 21 of 38)
ADDR
REGISTER NAME
Line Pickup (Read/Write Grouped Setting)
71F0
Line Pickup Function
71F1
Line Pickup Signal Source
71F2
Line Pickup Phase IOC Pickup
71F3
Line Pickup Pos Seq UV Pickup
71F4
Line End Open Pickup Delay
71F5
Line End Open Reset Delay
71F6
Line Pickup Pos Seq OV Pickup Delay
71F7
Autoreclose Coordination Pickup Delay
71F8
Autoreclose Coordination Reset Delay
71F9
Autoreclose Coordination Bypass
71FA
Line Pickup Block
71FB
Line Pickup Target
71FC
Line Pickup Events
Breaker Failure (Read/Write Grouped Setting) (2 modules)
7200
Breaker Failure x Function
7201
Breaker Failure x Mode
7208
Breaker Failure x Source
7209
Breaker Failure x Amp Supervision
720A
Breaker Failure x Use Seal-In
720B
Breaker Failure x Three Pole Initiate
720C
Breaker Failure x Block
720D
Breaker Failure x Phase Amp Supv Pickup
720E
Breaker Failure x Neutral Amp Supv Pickup
720F
Breaker Failure x Use Timer 1
7210
Breaker Failure x Timer 1 Pickup
7211
Breaker Failure x Use Timer 2
7212
Breaker Failure x Timer 2 Pickup
7213
Breaker Failure x Use Timer 3
7214
Breaker Failure x Timer 3 Pickup
7215
Breaker Failure x Breaker Status 1 Phase A/3P
7216
Breaker Failure x Breaker Status 2 Phase A/3P
7217
Breaker Failure x Breaker Test On
7218
Breaker Failure x Phase Amp Hiset Pickup
7219
Breaker Failure x Neutral Amp Hiset Pickup
721A
Breaker Failure x Phase Amp Loset Pickup
721B
Breaker Failure x Neutral Amp Loset Pickup
721C
Breaker Failure x Loset Time
721D
Breaker Failure x Trip Dropout Delay
721E
Breaker Failure x Target
721F
Breaker Failure x Events
7220
Breaker Failure x Phase A Initiate
7221
Breaker Failure x Phase B Initiate
7222
Breaker Failure x Phase C Initiate
7223
Breaker Failure x Breaker Status 1 Phase B
7224
Breaker Failure x Breaker Status 1 Phase C
7225
Breaker Failure x Breaker Status 2 Phase B
7226
Breaker Failure x Breaker Status 2 Phase C
7227
...Repeated for module number 2
Phase Directional (Read/Write Grouped Setting) (2 modules)
7260
Phase DIR 1 Function
7261
Phase DIR 1 Source
7262
Phase DIR 1 Block
7263
Phase DIR 1 ECA
GE Power Management
RANGE
0 to 1
0 to 5
0 to 30
0 to 3
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 1
0 to 1
0 to 65535
0 to 65535
0.001 to 30
0.001 to 30
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 1
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0.001 to 30
0.001 to 30
0.001 to 30
0.001 to 30
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 5
0 to 65535
0 to 359
L90 Line Differential Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F167
pu
0.001
F001
pu
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F102
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F157
---
1
F167
---
1
F126
---
1
F126
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F126
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F167
---
1
F300
---
1
F001
DEFAULT
0 (Disabled)
0 (SRC 1)
1000
700
B
150
90
40
45
5
1 (Enabled)
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (3-Pole)
0 (SRC 1)
1 (Yes)
1 (Yes)
0
0
1050
1050
1 (Yes)
0
1 (Yes)
0
1 (Yes)
0
0
0
0
1050
1050
1050
1050
0
0
0 (Self-reset)
0 (Disabled)
0
0
0
0
0
0
0
0 (Disabled)
0 (SRC 1)
0
30
B-29