B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 20 of 38)
ADDR
REGISTER NAME
65C5
Power Swing Fwd Rca
65C6
Power Swing Rev Reach
65C7
Power Swing Rev Rca
65C8
Outer Limit Angle
65C9
Middle Limit Angle
B
65CA
Inner Limit Angle
65CB
Delay 1 Pickup
65CC
Delay 1 Reset
65CD
Delay 2 Pickup
65CE
Delay 3 Pickup
65CF
Delay 4 Pickup
65D0
Seal In Delay
65D1
Trip Mode
65D2
Power Swing Block
65D3
Power Swing Target
65D4
Power Swing Event
Load Encroachment (Read/Write Grouped Setting)
6700
Load Encroachment Function
6701
Load Encroachment Source
6702
Load Encroachment Min Volt
6703
Load Encroachment Reach
6704
Load Encroachment Angle
6705
Load Encroachment Pkp Delay
6706
Load Encroachment Rst Delay
6707
Load Encroachment Block
6708
Load Encroachment Target
6709
Load Encroachment Events
670A
Load Encroachment Reserved (6 items)
Phase Undervoltage (Read/Write Grouped Setting) (2 modules)
7000
Phase UV1 Function
7001
Phase UV1 Signal Source
7002
Phase UV1 Pickup
7003
Phase UV1 Curve
7004
Phase UV1 Delay
7005
Phase UV1 Minimum Voltage
7006
Phase UV1 Block
7007
Phase UV1 Target
7008
Phase UV1 Events
7009
Phase UV Measurement Mode
700A
Reserved (6 items)
7010
...Repeated for module number 2
Phase Overvoltage (Read/Write Grouped Setting)
7100
Phase OV1 Function
7101
Phase OV1 Source
7102
Phase OV1 Pickup
7103
Phase OV1 Delay
7104
Phase OV1 Reset Delay
7105
Phase OV1 Block
7106
Phase OV1 Target
7107
Phase OV1 Events
7108
Reserved (8 items)
Distance (Read/Write Grouped Setting)
7120
Distance Signal Source
7121
Memory Duration
B-28
RANGE
40 to 90
0.1 to 500
40 to 90
40 to 140
40 to 140
40 to 140
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 5
0 to 3
0.02 to 250
5 to 50
0 to 65.535
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 1
0 to 5
0 to 3
0 to 1
0 to 600
0 to 3
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 5
0 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 5
5 to 25
L90 Line Differential Relay
APPENDIX B
UNITS
STEP
FORMAT
º
1
F001
ohms
0.01
F001
º
1
F001
º
1
F001
º
1
F001
º
1
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F514
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F167
pu
0.001
F001
Þ
0.01
F001
°
1
F001
s
0.001
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
---
1
F111
s
0.01
F001
pu
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F186
0 (Phase to Ground)
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F167
cycles
1
F001
GE Power Management
DEFAULT
75
5000
75
120
90
60
30
50
17
9
17
400
0 (Delayed)
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (SRC 1)
250
100
30
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
0 (Definite Time)
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
100
100
0
0 (Self-reset)
0 (Disabled)
0
0 (SRC 1)
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

L90

Table of Contents