Power System - GE UR Series Instruction Manual

Line differential relay.
Hide thumbs
   
1
2
3
4
Table of Contents
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470

Advertisement

5 SETTINGS
b) VOLTAGE BANKS
ÖØ
PATH: SETTINGS
SYSTEM SETUP
VOLTAGE BANK X5
MESSAGE
MESSAGE
MESSAGE
MESSAGE
MESSAGE
'X' = F, M, or U. 'F', 'M', and 'U' are module slot position letters. See also the INTRODUCTION TO AC SOURCES section.
Up to 3 banks of phase/auxiliary VTs can be set.
With VTs installed, the relay can be used to perform voltage measurements as well as power calculations. Enter the
made to the system as "Wye" or "Delta". An open-delta source VT connection would be entered as
VT xx CONNECTION
"Delta". See the typical wiring diagram in the HARDWARE chapter for details.
The nominal Phase VT Secondary Voltage setting is the voltage across the relay input terminals when nominal volt-
age is applied to the VT primary.
NOTE
For example, on a system with a 13.8 kV nominal primary voltage and with a 14400:120 Volt VT in a Delta connec-
tion, the secondary voltage would be 115, i.e. (13800 / 14400) × 120. For a Wye connection, the voltage value
entered must be the phase to neutral voltage which would be 115 /
On a 14.4 kV system with a Delta connection and a VT primary to secondary turns ratio of 14400:120, the voltage
value entered would be 120, i.e. 14400 / 120.
ÖØ
PATH: SETTINGS
SYSTEM SETUP

POWER SYSTEM

MESSAGE
MESSAGE
MESSAGE
The power system
NOMINAL FREQUENCY
cannot be measured from available signals. This may happen if the signals are not present or are heavily distorted. Before
reverting to the nominal frequency, the frequency tracking algorithm holds the last valid frequency measurement for a safe
period of time while waiting for the signals to reappear or for the distortions to decay.
The phase sequence of the power system is required to properly calculate sequence components and power parameters.
The
setting matches the power system phase sequence. Note that this setting informs the relay of the
PHASE ROTATION
actual system phase sequence, either ABC or ACB. CT and VT inputs on the relay, labeled as A, B, and C, must be con-
nected to system phases A, B, and C for correct operation.
GE Power Management
Ö
ÖØ
AC INPUTS
VOLTAGE BANK X1
PHASE VT X5
CONNECTION: Wye
PHASE VT X5
SECONDARY: 66.4 V
PHASE VT X5
RATIO: 1.00 :1
AUXILIARY VT X5
CONNECTION: Vag
AUXILIARY VT X5
SECONDARY: 66.4 V
AUXILIARY VT X5
RATIO: 1.00 :1
ÖØ
POWER SYSTEM
NOMINAL FREQUENCY:
60 Hz
PHASE ROTATION:
ABC
FREQUENCY AND PHASE
REFERENCE: SRC 1
FREQUENCY TRACKING:
Enabled
value is used as a default to set the digital sampling rate if the system frequency
L90 Line Differential Relay
5.3 SYSTEM SETUP
Range: Wye, Delta
Range: 50.0 to 240.0 V in steps of 0.1
Range: 1.00 to 24000.00 in steps of 1.00
Range: Vn, Vag, Vbg, Vcg, Vab, Vbc, Vca
Range: 50.0 to 240.0 V in steps of 0.1
Range: 1.00 to 24000.00 in steps of 1.00
3
= 66.4.
5.3.2 POWER SYSTEM
Range: 25 to 60 Hz in steps of 1
Range: ABC, ACB
Range: SRC 1, SRC 2,..., SRC 6
Range: Disabled, Enabled
PHASE
5
5-25

Advertisement

Table of Contents

   Also See for GE UR Series

   Related Manuals for GE UR Series

This manual is also suitable for:

L90

Comments to this Manuals

Symbols: 0
Latest comments: