B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 8 of 38)
ADDR
REGISTER NAME
303E
...Repeated for module number 8
3040
...Repeated for module number 9
3042
...Repeated for module number 10
Modbus File Transfer (Read/Write)
3100
Name of file to read
B
Modbus File Transfer (Read Only)
3200
Character position of current block within file
3202
Size of currently-available data block
3203
Block of data from requested file (122 items)
Event Recorder (Read Only)
3400
Events Since Last Clear
3402
Number of Available Events
3404
Event Recorder Last Cleared Date
Event Recorder (Read/Write Command)
3406
Event Recorder Clear Command
DCMA Input Values (Read Only) (24 modules)
34C0
DCMA Inputs x Value
34C2
...Repeated for module number 2
34C4
...Repeated for module number 3
34C6
...Repeated for module number 4
34C8
...Repeated for module number 5
34CA
...Repeated for module number 6
34CC
...Repeated for module number 7
34CE
...Repeated for module number 8
34D0
...Repeated for module number 9
34D2
...Repeated for module number 10
34D4
...Repeated for module number 11
34D6
...Repeated for module number 12
34D8
...Repeated for module number 13
34DA
...Repeated for module number 14
34DC
...Repeated for module number 15
34DE
...Repeated for module number 16
34E0
...Repeated for module number 17
34E2
...Repeated for module number 18
34E4
...Repeated for module number 19
34E6
...Repeated for module number 20
34E8
...Repeated for module number 21
34EA
...Repeated for module number 22
34EC
...Repeated for module number 23
34EE
...Repeated for module number 24
RTD Input Values (Read Only) (48 modules)
34F0
RTD Inputs x Value
34F1
...Repeated for module number 2
34F2
...Repeated for module number 3
34F3
...Repeated for module number 4
34F4
...Repeated for module number 5
34F5
...Repeated for module number 6
34F6
...Repeated for module number 7
34F7
...Repeated for module number 8
34F8
...Repeated for module number 9
34F9
...Repeated for module number 10
34FA
...Repeated for module number 11
34FB
...Repeated for module number 12
34FC
...Repeated for module number 13
B-16
RANGE
---
0 to 4294967295
0 to 65535
0 to 65535
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
-9999.999 to 9999.999
-32768 to 32767
L90 Line Differential Relay
APPENDIX B
UNITS
STEP
FORMAT
---
---
F204
---
1
F003
---
1
F001
---
1
F001
---
1
F003
---
1
F003
---
1
F050
---
1
F126
---
0.001
F004
°C
1
F002
GE Power Management
DEFAULT
(none)
0
0
0
0
0
0
0 (No)
0
0

Advertisement