UPNP CONFIGURATION

Configuration
UPNP
Configure UPnP on this page.
Mode
Indicates the UPnP operation mode. Possible modes are:
Enabled: Enable UPnP mode operation.
Disabled: Disable UPnP mode operation.
When the mode is enabled, two ACEs are added automatically to trap UPNP related packets to
CPU. The ACEs are automatically removed when the mode is disabled.
TTL
The TTL value is used by UPnP to send SSDP advertisement messages. Valid values are in
the range 1 to 255.
Advertising Duration
The duration, carried in SSDP packets, is used to inform a control point or control points how
often it or they should receive an SSDP advertisement message from this switch. If a control
point does not receive any message within the duration, it will think that the switch no longer
exists. Due to the unreliable nature of UDP, in the standard it is recommended that such
refreshing of advertisements to be done at less than one-half of the advertising duration. In the
implementation, the switch sends SSDP messages periodically at the interval one-half of the
advertising duration minus 30 seconds. Valid values are in the range 100 to 86400.
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved
values.
PAGE 246
OPTICAL SYSTEMS DESIGN
OSD2512 OPERATOR MANUAL
DOC ID: 10118101