Optical Systems Design OSD2512 User Manual page 131

Managed 12 x 10/100/1000base-t rj45 and 2 x 1g sfp ethernet switch
Hide thumbs Also See for OSD2512:
Table of Contents

Advertisement

General Settings
Enable Loop Protection
Controls whether loop protections is enabled (as a whole).
Transmission Time
The interval between each loop protection PDU sent on each port. Valid values are 1 to 10
seconds. Default value is 5 seconds.
Shutdown Time
The period (in seconds) for which a port will be kept disabled in the event of a loop is detected
(and the port action shuts down the port). Valid values are 0 to 604800 seconds (7 days). A
value of zero will keep a port disabled (until next device restart). Default value is 180 seconds.
Port Configuration
Port
The switch port number of the port.
Enable
Controls whether loop protection is enabled on this switch port.
Action
Configures the action performed when a loop is detected on a port. Valid values are
Shutdown Port, Shutdown Port and Log or Log Only.
Tx Mode
Controls whether the port is actively generating loop protection PDU's, or whether it is just
passively looking for looped PDU's.
Buttons
: Click to save changes.
: Click to undo any changes made locally and revert to previously saved
values.
PAGE 131
OPTICAL SYSTEMS DESIGN
OSD2512 OPERATOR MANUAL
DOC ID: 10118101

Advertisement

Table of Contents
loading

Table of Contents