Siemens SINUMERIK 840Di Function Manual page 1296

Basic machine
Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Detailed Description
2.12 Block descriptions
END_VAR
Description of formal parameters
The table below lists all formal parameters of the PUT function.
Signal
Req
NumVar
Addr1 to Addr8
Unit 1 to Unit 8
Column 1 to
Column 8
Line 1 to Line 8
Error
Done
State
SD1 to
SD8
Error identifiers
If it was not possible to execute a job, the failure is indicated by "logic 1" on status parameter
error. The error cause is coded at the block output State:
State
WORD H
1 to 8
0
2-102
SD1 :
SD2 :
SD3 :
SD4 :
SD5 :
SD6 :
SD7 :
SD8 :
Type Type
I
Bool
I
Int
I
Any
I
Byte
I
Word
I
Word
Q
Bool
Q
Bool
Q
Word
I/O
Any
Meaning
WORD L
1
Access error
2
Error in job
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
ANY ;
Value range
1 to 8
(corresponds to use of
Addr1 to Addr8)
[DBName].[VarName]
P#Mm.n BYTE x...
P#DBnr.dbxm.n BYTE x
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Remarks
Job start with positive signal edge
Number of variables to be written
Variable identifiers from NC Var
selector
Area address, optional for variable
addressing
Column address, optional for
variable addressing
Line address, optional for variable
addressing
Negative acknowledgment of job or
execution of job impossible
Job successfully executed
See error identifiers
Data to be written
Note
In high byte number of Var in which
error occurred
Incorrect compilation of Var in a job
PLC Basic Program Solution Line (P3 sl)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents