Siemens SINUMERIK 840Di Function Manual page 1253

Basic machine
Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

840D: MPI connection
If an MPI connection is used for the MCP and HHU, these components must be taken into
account in the configuration for global data in STEP7 (NetPro). Although the addresses of
the MCP and HHU can be stored anywhere, we recommend a free input and output image
area. These start addresses must also be stored in the pointer parameters of the FB1. The
FB1 parameters listed below are used for further parameterization.
Setting MCP1Stop, MCP2Stop, BHGStop = 1 will suppress time monitoring. MCP failed
interrupts are suppressed.
Once the configuration has been compiled in NetPro, the SDB 210 in the SDB container will
need to be loaded on the PLC.
Fig. 2-18
Relevant parameters (FB1)
MCP
MCPNum=1 or 2 (number of MCPs)
MCP1In
MCP1Out
MCP1StatSend
MCP1StatRec
MCP1Timeout
MCPMPI = TRUE
MCP1Stop
MCPSDB210 = TRUE
MCPCopyDB77 = TRUE or FALSE
MCPBusType = B#16#00
(all pointer entries as parameterized in SDB210 global data)
PLC Basic Program Solution Line (P3 sl)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
MPI connection
MCP2In
MCP2Out
MCP2StatSend
MCP2StatRec
MCP2Timeout
MCP2Stop
2.7 Structure and functions of the basic program
HHU
HHU = 1 (MPI)
BHGIn
BHGOut
BHGStatSend
BHGStatRec
BHGTimeout
BHGMPI = TRUE
BHGStop
Detailed Description
2-59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents