Detailed description
2.12 Block descriptions
Explanation of the formal parameters
The table below shows all formal parameters of the "MCP_IFT" function:
Signal
BAGNo
ChanNo
SpindleIFNo
FeedHold
SpindleHold
Call example
CALL FC 25 (
With these parameter settings, the signals are sent to the 1st mode group, the 1st channel
and all axes. In addition, the spindle override is transferred to the 4th axis/spindle interface.
The feed hold signal is passed to bit memory 22.0 and the spindle stop signal to data block
DB2, data bit 151.0.
2-242
I/O
Type
I
Byte
I
Byte
I
Byte
Q
Bool
Q
Bool
BAGNo :=
ChanNo :=
SpindleIFNo :=
FeedHold :=
SpindleHold :=
Value range
0 - b#16#0A
and
b#16#10 - b#16#1A
0 - B#16#0A
0 - 31
(B#16#1F)
//Machine control panel T variants
//signals to interface
B#16#1,
B#16#1,
B#16#4,
m22.0,
db2.dbx151.0);
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Remarks
No. of mode group to which the
mode signals are transferred.
ModeGroupNo >= b#16#10 means
access to the second machine
control panel.
Channel no. for the channel signals
Number of the axis interface
declared as a spindle
Feed stop from machine control
panel, modal
Spindle stop from machine control
panel, modal
//Mode group no. 1
//Channel no. 1
//Spindle interface
//number = 4
//Feed stop signal
//modal
//Spindle stop modal in
//message DB
Power Line Basic PLC Program (P3)