Activating The "Predefined Connection Set - Siemens SINAMICS S120 Commissioning Manual

Canopen interface
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

3.4.5

Activating the "predefined connection set"

Introduction
Note
The STARTER commissioning tool is in OFFLINE mode.
Activating the "predefined connection set"
To activate the "predefined connection set", carry out the following steps:
1. In the project navigator, open the expert list for the drive as follows: Drive_1 > right-click >
2. Find parameter p8744 (see screenshot above).
3. Choose "Predefined connection set (1)" to set the "predefined connection set".
4. Repeat steps 1 to 3 for the next SINAMICS drive object, Drive_2. Note: SINAMICS S110
CANopen interface
Commissioning Manual, (IH2), V2.6, 10/2008 Edition, 6SL3097-2AA00-0BP3
3.4 Configuring the drive unit using the STARTER commissioning tool
Expert > Expert list.
Figure 3-17
Predefined connection set
only supports one drive.
Commissioning
93

Hide quick links: