The digital watchdog duration can be controlled in the following way.
Time-out selection with T = 1.08ms (TBC)

3.1.10. NMI control

CPLD
Address
READ
n97*
BATFEN
WRITE
n97*
BATFEN
Power-up Default
WDNMI
: When high, signal NMI from watchdog time-out.
WDNMIEN
: Enable NMI generation from digital watchdog
BATFLT
: When high, signal NMI from local RTC battery monitor
BATFEN
: Enable NMI generation for bat fault.
WDD[2..0]
000
001
010
011
100
101
110
111
262144T
D7
D6
D5
BATFLT
NU
NU
NU
0
NMI(T)
RESET(T)
16T
NMI(T)+8T
64T
NMI(T)+8T
256T
NMI(T)+8T
1024T
NMI(T)+8T
4096T
NMI(T)+8T
16384T
NMI(T)+8T
65536T
NMI(T)+8T
NMI(T)+8T
D4
D3
NU
NU
NU
NU
3.6
D2
D1
D0
NU
WDNMIEN
WDNMI
NU
WDNMIEN
NU
0