2.7

[Restore default parameters (Obj. 1011h)]

[Restore default parameters (Obj. 1011h: 00h)]

Data Type
Access
U8
RO
Description
The total number of Sub Index is returned. Supported Sub Index differ depending on the Network. The following shows the
Network and supported Sub Index.
Network
Default
CC-Link IE TSN
01h

[Restore all default parameters (Obj. 1011h: 01h)]

Data Type
Access
U32
RW
Description
All parameters (servo parameters and network parameters) that can be stored in the non-volatile memory can be reset to the
factory setting. To reset the servo parameters and network parameters to the factory setting, write "64616F6Ch" (= reverse
order of ASCII code of "load") in this object, and cycle the power or reset the software.
The read value is always "1" (initializing values).
2 General Objects
16
2.7 [Restore default parameters (Obj. 1011h)]
Mapping
Default
Impossible
Range
Description
01h (fixed)
Sub Index 1 is supported.
Mapping
Default
Impossible
00000001h
Range
Units
Range
Units
00000000h to
FFFFFFFFh
Save
Parameter
Impossible
Save
Parameter
Impossible