13.8

[Quick stop deceleration (Obj. 6085h)]

[Quick stop deceleration (Obj. 6085h: 00h)]

Data Type
Access
U32
RW
Description
Set a deceleration time constant for the Quick stop function. Set the time from the servo motor rated speed to stop. If the
setting value is "0", the deceleration time constant is 100 ms.
Unit
ms
Mapping
Default
RXMAP
Supported servo parameter
[Pr. PC24]
Range
Units
acc units
Initial value
100
13 Profile Position Mode Objects
13.8 [Quick stop deceleration (Obj. 6085h)]
Save
Parameter
Possible
Range
0 to 20000
13