3.2

[2nd Receive PDO Mapping (Obj. 1601h)]

[2nd Receive PDO Mapping (Obj. 1601h: 00h)]

Data Type
Access
U8
RO
Description
Indicates the total number of objects included in PDO. To set a value in an object of Sub Index 1 or later, write "00h" in the
object. After setting the value for objects of Sub Index 1 or later, write the total number of objects mapped to PDO.
Mapping
Default
Impossible
Range
Units
00h to 20h
3.2 [2nd Receive PDO Mapping (Obj. 1601h)]
Save
Parameter
Impossible
PDO mapping
3 PDO Mapping Objects