3-3-2 Laser pumping: LSR

Controls the laser pumping ON/OFF.
⿎ Setting request data / response data for readout
Start
LSR
Sub command
code
Sub command is "S" for the setting request data and "A" for the response data for readout.
⿎ Readout request data
Start
LSR
code
⿎ Data description
Name
Data length [byte]
Laser pumping
control
Total data
length
• This command is available only when the laser pumping control method is set to "communication commands" by Laser
Marker NAVI smart.
• From sending the laser pumping on request to completion of laser pumping, the following time will be required.
• LP-GS series: about 8 to 15 seconds
• LP-RC series: about 10 seconds
• LP-RF series: about 7 seconds
• LP-RV series: about 1 second
• For LP-RC series, the shutter can be opened after turning on the laser pumping. When the laser pumping is turned to
off, the shutter is closed automatically.
• Response data when reading out this command returns the laser pumping control status. If you want to check the laser
pumping ON/OFF status, use the status checking (STS) command.
• When you turn OFF the laser pumping during marking laser processing (laser radiation), an error occurs and this
interrupts the marking trigger processing.
⿎ Example of command settings
Condition:
Laser pumping control = 1
• Setting
Transmission data
• Readout
Transmission data
Response data
[Laser pumping control]
R
(Check sum)
Data contents
"0": Laser pumping OFF
1
"1": Laser pumping ON
1
The data length is fixed.
[STX]
LSR
[STX]
LSR
[STX]
LSR
ME-LP-GS-SR-COMP-3
(Check sum)
1-byte
End code
S
1
[CR]
R
[CR]
A
1
[CR]
End code
Remarks