Priming - H.C Duke & Son Electro-Freeze Genesis Series Operator’s Manual With Illustrated Parts List

Combination soft serve and shake freezer
Hide thumbs Also See for Electro-Freeze Genesis Series:
Table of Contents

Advertisement

ELECTRO FREEZE Soft Serve Model GEN-2080
12.1 Sanitizing Instructions
12. Leaving the spigots open, press L1
& R1 keys to turn the beaters "OFF"
and let the MTS force all possible
sanitizer out of the freezing cylinders.
NOTE: Some sanitizer will remain in
hoses and cylinder.
13. Press L2 & R2 keys to turn the MTS
pumps "OFF".

12.2 Priming

Priming the freezer removes all excess air and sanitizer from the freezing cylinder
and sets the proper overrun for the first cylinder of product.
1. Wash and sanitize your hands and
forearms.
2. Holding the top 6-inch (15cm) portion
only, insert each pickup tubes into the
sanitized mix tank through the small hole
in the rear cover and set tanks in the
cabinet.
3. Slide each boot seal down on the mix
tank cover.
4. Fill the mix tanks with mix and install
the front covers.
5. Insert each sanitized mix probes
through the large hole in the rear cover,
and connect the probe cords to the
Cover - Must be
in place to operate.
Mix Level
Probe Cord
Mix Pickup Tube
Mix Tank
Mix Level Probe
Figure 12-1
52
— Soft Serve
Mix Level
Probe Cord
Mix Pickup Tube
Mix Tank
Mix Level Probe
— Soft Serve(continued)
14. Remove the pickup tubes, holding the
top 6" portion only.
15. Remove the mix tanks and empty any
remaining sanitizer.
probes and to the back of the
cabinet.
6. Close the cabinet door.
7. Place an empty container under the
dispense head on the drip tray.
8. Pull up the air bleed plugs
9. Open the side spigots.
10. Press L2 & R2 keys to turn the MTS
pumps "ON" allowing the mix to push the
remaining sanitizer from the freezer.
11. Close the spigots one at a time when
pure mix is coming out.
Failure to completely remove
sanitizer or water from the freezing
cylinder before placing in "FREEZE"
will cause the scraper blades to break
and damage the freezer.
12. Allow the MTS to fill the cylinder
until mix flows from the bottom of the air
Cover - Must be
in place to operate.
bleed plug openings in the bottom of the
dispense head, close the air bleed plugs.
Wait for the MTS to fill the cylinders and
shut off.
13. After the cylinders are pressurized
and the MTS has cycled off
(approximately 30 seconds) Press the left
and right "Freeze" keys.
14. Allow the freezer to cycle for 15
minutes. The product is now ready to
serve.
Important:
185240

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gen-2080

Table of Contents